Solar playing up?


Hi  Our solar system (2x100w panels with a new1x 120agm battery) was working fine. We did a 9 day free camp last year with helping out with a genie of course and all went well. Then last week we had full sun and it was only going up to 12. Put genie on went up to 13 only then when we turned genie off it dropped immediately to 12.2 but showed .9 going in at night. The next day showed nothing going in when in the full sun but at night showed 1.0 going in?????

Kim



__________________


Guru

Status: Offline
Posts: 7640
Date:

Full moon or parked under a street light ? I suggest it's zero at night and the gauge is not calibrated ..

__________________
Whats out there


Senior Member

Status: Offline
Posts: 248
Date:

Hi Yes I know it is supposed to be zero and has been up until last week but wondering what may have gone wrong to cause the strange things it is doing.



__________________


Member

Status: Offline
Posts: 23
Date:

Hi folks. I have never had much success with the regulator that is supplied with the panels. Might be a thought, easy to bypass them but of course you need a good one in the line. Cheers all. Woody46



__________________
R.V.Woodbridge


Senior Member

Status: Offline
Posts: 222
Date:

@Woody46. You mean running the pannels directly to the bateries with no regulator? When I my regulator blew up I started doing exactly that however making sure I did not over charge the batteries. The main problem I can see is that it is an impeadance mismatch and thus an inefficent power transfer AFAIK. A bit of a dilema when it would cost less to chuck in another 200w panel than to put in an impeadance matching power regualoter.



__________________

And I somehow rather fancy that I'd like to change with Clancy ..



Senior Member

Status: Offline
Posts: 406
Date:

First check would be all fuses. Second check would be wiring. Third check would be battery, even new ones can faulter. Fourth check would be the regulator. Fifth check would be each panel. A multimeter will be most helpful. Simply going through a process of check and eliminate to find the source causing the issue.

__________________

Cheers from Vince

VK2FBUZ



Member

Status: Offline
Posts: 23
Date:

Maybe I should have said a good regulator in line. Perhaps they have already done that. I don't like the elcheapo regulators that come with panels. Cheers all. Woody46



__________________
R.V.Woodbridge


Senior Member

Status: Offline
Posts: 248
Date:

Thank you all but especially Vince for the common sense approach as we are not tech savvy. Hubbie had checked all fuses and today will do the rest in order. Found someone hear with a meter. Will let you know how we go.

Cheers

Kim



__________________


Guru

Status: Offline
Posts: 4712
Date:

Muzzlehatch wrote:

@Woody46. You mean running the pannels directly to the bateries with no regulator? When I my regulator blew up I started doing exactly that however making sure I did not over charge the batteries. The main problem I can see is that it is an impeadance mismatch and thus an inefficent power transfer AFAIK. A bit of a dilema when it would cost less to chuck in another 200w panel than to put in an impeadance matching power regualoter.


 Mark, please explain this impedance mismatch?

 



__________________

PeterD
Nissan Navara D23 diesel auto, Spaceland pop-top
Retired radio and electronics technician.
NSW Central Coast.

 



Senior Member

Status: Offline
Posts: 222
Date:

AFAIK the MPPT type charge controller is a switchmode regulator - essentially a DC / AC / DC transformer that matches the aparent internal resistance of the PV array to the internal resistance of the battery pack and keeps that tracking despite level of charge on the batteries and amount of current available from the PV array. When the  Impeadance of the load equals the impeadance of the power source maximum power transfer can take place. Obviously it also has charge cutout to prevent overcharge as well.

Ref: https://en.wikipedia.org/wiki/Maximum_power_transfer_theorem

I hope I am not "Nuking It" . I.E. "In theory there is no difference between theory and practice but in practice there is."

 

 



__________________

And I somehow rather fancy that I'd like to change with Clancy ..



Guru

Status: Offline
Posts: 4712
Date:

A solar panel does not have an impedance that you can define so the theory you quoted does not apply. The other thing, who said the OP has an MPPT regulator. If he has a PWM regulator then when it is working flat out it approximates a solar panel connected to the battery through a diode.



__________________

PeterD
Nissan Navara D23 diesel auto, Spaceland pop-top
Retired radio and electronics technician.
NSW Central Coast.

 



Senior Member

Status: Offline
Posts: 222
Date:

Woody talks obliquely about not using a regulator at all. I have seen systems that just use a relay to switch off the panels once the batteries are up to charge.

I was always under the impression that by measuring the OC voltage (0watts) and the CC current (also 0watts) as well as setting up a load line at intermediate loads one could determine the point where the product of voltage and current i.e wattage was at its maximum. This then could be compared with the point at with the battery charge current was at it's optimum. It is likely theat the internal resistance (impeadance since it is non linear ) of load and source will not be the same.

The MPPT regulator dynamicly matches these two voltage / current ratios to each other. I am no expert.

My point is even with a rough as guts mismatch the choice is for the same money to wack up another 250 wattts of PV or increase effieciency with a MPPT regulator.



__________________

And I somehow rather fancy that I'd like to change with Clancy ..



Member

Status: Offline
Posts: 23
Date:

Hi all. I use a Power Tech MP3722 charge controller. My original point was the supplied controller will let you down. Anyway enough of this, I rather think that I would like to change with Clancy also, Wait on I'm a permanent traveller, I think I've at least joined him. Take It easy folks .Cheers. Woody46 l 



__________________