Post Info TOPIC: Solar Panels fuses and isolation switch ?


Member

Status: Offline
Posts: 20
Date:
Solar Panels fuses and isolation switch ?


Hi all

Just learning here and trying to tidy up my wiring in van have a couple of questions as follows 

1) Should I put a Isolation switch between Panels and Victron controller. ?

2) Put a fuse between Victron controller and Battery  ?

Any advise will be appreciated 

 

Paul



__________________


Guru

Status: Offline
Posts: 7579
Date:

I have a switch between panels & my Victron 100/20 & can also isolate individual sets for testing to chase down potential performance issues.

I have a fuse between the controller & battery.



__________________

Procrastination, mankind's greatest labour saving device!

50L custom fuel rack 6x20W 100/20mppt 4x26Ah gel 28L super insulated fridge TPMS 3 ARB compressors heatsink fan cooled 4L tank aftercooler Air/water OCD cleaning 4 stage car acoustic insulation.



Guru

Status: Offline
Posts: 5388
Date:

I am not a techie, but I am led to believe that it is important to have fuses

As I have a DC/DC controller (this allows the engine battery, and solar panels) to charge the house batteries

Plus I have solar on the roof, as well as a portable solar panel, I use circuit breakers

A circuit breaker can be used for both isolation and fuse application

Mine are set up between

Solar panel and controller
Controller and house battery
House battery and house wiring

Below is a pic of a circuit breaker, and you can buy them in different amps, I buy mine from eBay

Circuit breaker.png



__________________

Tony

It cost nothing to be polite



Guru

Status: Offline
Posts: 4375
Date:

There is absolutely no point in having a fuse or circuit breaker between the solar panels and the controller. The panels could never blow that fuse because they are effectively a constant power source.
We don't have an isolation switch between the panels and controller either. In the rare event of needing to disconnect the solar I can simply remove the cable from the controlled. A switch is just another loss in the system.
A fuse between the controller and the batteries (close to the controller) is arguable in case of a short to earth of that cable. We don't. The controller needs to be as close to the batteries as possible.
Cheers,
Peter

__________________

OKA196, 4x4 'C' Class, DIY, self contained motorhome. 960W of solar, 400Ah of AGMs, 310L water, 280L fuel. https://www.oka4wd.com/forum/members-vehicles-public/569-oka196-xt-motorhome
 

 



Guru

Status: Offline
Posts: 7642
Date:

I dont . I just isolate out of link box if required . With parallel system, theres 4 wires going into reg which wont fit . So all + from panels active link then one heavy wire goes to reg which just fits into connector. . From memory 6mm sq..

__________________
Whats out there


Guru

Status: Offline
Posts: 1327
Date:

Hi Paul,

I have an isolator on volts positive (+V) between solar panels and solar controller.

I have an isolator on volts positive (+V) to battery bank.

Why?

Any wiring alterations I need to make in the system, I can isolate all volts positive (+V) input to the batteries.

Insofar as fuses, the solar controller is protected internally from shorting. All other utility devices such as fridge, air heaters, water heaters, lights, 12v power outlets should be fuse protected.

12v tug to den connection, if fitted correctly, will also be fuse protected in engine bay.

Never over fuse a circuit (several fuses on same circuit) as each fuse can cause voltage loss. And if there is a failure on that circuit...which fuse has failed?

 

 



__________________

Cheers, Richard (Dick0)

"Home is where the Den is parked, Designer Orchid Special towed by Jeep Grand Cherokee Limited"

"4x250W solar panels, Epever 80A charger and 3x135Ah Voltax Prismatic LiFePO4 Batteries".



Guru

Status: Offline
Posts: 4375
Date:

Dick0 wrote:

Never over fuse a circuit (several fuses on same circuit) as each fuse can cause voltage loss. And if there is a failure on that circuit...which fuse has failed?

  


 ANY cable which has a power source (battery) at each end (like a DCDC connection) needs to be fused at each end as a short in the middle is a short to a battery and that is a disaster because of the huge currents that can flow.

It is also legitimate to have a branch power feed (larger fuse near the battery) which then divides into smaller feeds to various things. Each of those branches should be separately fused according to the cables.

Fuses and circuit breakers are to protect the cables from overload (and fire). They are not to protect the appliance.

Cheers,

Peter



__________________

OKA196, 4x4 'C' Class, DIY, self contained motorhome. 960W of solar, 400Ah of AGMs, 310L water, 280L fuel. https://www.oka4wd.com/forum/members-vehicles-public/569-oka196-xt-motorhome
 

 



Member

Status: Offline
Posts: 20
Date:

Great information from all that have responded

Thanks

Paul

__________________


Senior Member

Status: Offline
Posts: 155
Date: