Hi all,

 

I just had to report my bargain that I scored on the weekend.

I spotted some 36v 200W folding solar panels on Facebook last week and have been keenly waiting for the weekend, hoping there were some left in time for me to get from Newcastle to Sydney to pick them up.

As luck would have it they had plenty left. I originally went down to pick up a single 160w set $100. That was my plan anyway.

I ended up walking away with 2 x 200w sets for $120 a piece. biggrin

 

Why the 36V panels ? well, my set up includes an mppt controller and old house panels which match the voltages of the new panels nicely.

I like this set up as I have 2 185w panels on the van connected in parallel. The way I figure it, is I kinda get the best of both worlds (series v parallel) . I get the higher voltages of the 36v panels and the benefits that this provides, like smaller gauge cabling etc, albeit that I prefer over kill in this area and still went with cables appropriately sized for 12v panels.

It cost, but I think it's worth the piece of mind in this area.

Having them in parallel affords me the benefits in situations like partial shade and the like, whilst keeping the input voltage at the controller and in the cable runs down to a reasonable level.

With all that in mind, full shade means no power and I ain't moving my van to chase the sun, so thought I'd keep an eye out for something I could use as a portable add on to my existing system.

I had previously been stowing a massive 235w panel in the van as a back up when I think I needed it, but when I say massive, it's huge and could never be considered a long term prospect.

 

To that end, when I spotted these folding panels in a 36v, knowing how rare they are and for that price, I jumped at the deal.

Even if they were standard panels, it would have still been a good deal.

 

Whilst I have no association with old mate selling these, I was told they had something like 20 sets left, if anyone is chasing some.

here's the market place ad if anyone is interested (hope this works ) https://www.facebook.com/marketplace/item/376417766317212/?ref=messenger_banner

 

here's the pic from the ad

 

cases.JPG

 

the sticker shows them as solarworld panels, which I admit, I have not heard of. Not that that means anything. there are so many in the market.

 

a review website here https://www.solarquotes.com.au/panels/solarworld-review.html  gives them a 4.7 out of 5 . keep in mind, these a house installations but I still think its relevant.

 

These guys are big at 20kg but the 160s were only 3kg lighter and 20 bucks cheaper, thus I came home with the 2 x 200s .

I opened them up for the first time and did some quick tests to make sure they were inline with the specs they were sold as and the sticker on the back.

here they are in the back yard set up for testing which they passed well. oc volatages tested at 44v a piece. Happy days.

 

 

2panels.jpg

 

it's not the best time of year to be getting proper results out of them but thus far, I'm happy as a pig in it.

oh on a similar note, someone on another forum mentions these linear 12v acutators to me. In due time, I might try and work a few of these into the set up but am all ears to anyone who has already done it and bonus points are to be had for pics of the set up.

act.JPG

 

 

As always, here's the video of me opening them for the first time and running through some quick tests. They appear to be very well made and have the best legs I've seen on a set of portable panels biggrin

 

 

cheers Brett

 

 

 



Attachments
__________________


Guru

Status: Offline
Posts: 1315
Date:

Hi Brett, great video. Have you thought about adding the short circuit current test to go along with the voltage test? I have a lot of semi flexible panels that pass the open circuit voltage test but fail the short circuit current test. Both specs are marked on the back of the panel and it is great method of getting the right angle to the sun for max output as well, the open circuit voltage doesn't change, but the short circuit current does.

T1 Terry


__________________

You can lead a head to knowledge but you can't make it think. One day I'll know it all, but till then, I'll keep learning.

Any links to any sites or products is not an endorsement by me or do I gain any financial reward for such links 



Senior Member

Status: Offline
Posts: 386
Date:

you're probably right, I did set up one set up to the van and the output seemed ok for where they were situated. can't wait for some proper sunny months.

What I need to do, is get myself a current clamp. There's been so many times one of those would have come in handy rather than messing about with inline meters.

I'm going to do some tests and knock up a video on angle and temps to show their impact on output.....eventually.
When I had the panels, now on the van but had them just sitting on the roof without any air gaps under them, the heat in the panel was crazy.
I couldn't even touch them they were so hot.
After I hit them with the hose, the out put came up quite a bit. I'm guessing 10-20% very roughly.
Still, not going to be spraying my panels too often.

thanks for the compliment on the vid and the tip.

Since you have some back ground, have you any input into the lifters on the panels or seen something on your travels that might be useful ?
Trying to formulate a plan at this stage.


cheers Brett

__________________


Guru

Status: Offline
Posts: 1315
Date:

Aligning solar panels to the sun on an RV can be a real nightmare. The vibrations make just about any sort of latching eventually let go and the panel array suddenly becomes a sail with not near enough anchoring. You arrive at the free camp and have no idea where the solar array ended up. I have even had stainless bolts with spring washers undo themselves, fortunately on a motorhome you hear the noise of the array flapping up and down, you wouldn't hear that on the roof of a caravan.
To work effectively the array needs to tilt on 2 planes to do the solar tracking from sun up to sun down and correctly angled to the horizon. Hard enough on a ground mounted system but getting the RV lined up facing perfectly east/west so the angle to the horizon only needs to be set up once for the day is close to impossible. That means both angles need to be adjust every 15 mins to get the ultimate sun angle.
Then there is the over cast day or light scattered cloud day, the panels flat mounted produce more than when perfectly angled to the sun.
There are multiple auto adjusting 2 plane solar trackers for sale on evil bay and suit a ground based solar array, but you can't have them opening up while travelling and still expect them to be there when you arrive :lol:
The solar array on my Mazda E3500 pivots from either end, mostly for ease of cleaning under them, but a few times in winter in the Victorian high country I've tilted them and used a leg each side to hold the panels up, first time at roughly a 45* angle. Worked well until the wind came up, too dangerous to try and drop them down again while it was windy so spent the night just waiting for the whole thing to rip off the roof or the glass part to tear out of the frames, never get them above 30* or so now. That does help but not as much as you would think because there is no east/west tracking as well.
Is it worth the effort? on a ground based system, most certainly, more than a 50% increase in the full day harvest during winter, but on an RV, more to be gained by designing a system using small panels like the 60w units and covering the roof where ever a panel can be squeezed in. Shade from a hatch or the air cond will only be on those panels for part of the day when the suns out, but harvest all day when it is cloudy or raining. This type of set up does not suit MPPT control though unless you have multiple controllers and they can be configured in a master/slave set up. Series/parallel into one controller results in every panel in the string where one panel is shaded dropping out if the other parallel string is in full sun.
PWM control works best for these set ups, but it requires all the solar wiring to go to the battery compartment and controlled using multiple solid state relays with one master controller. Simple operating system yet complicated to get your head around initially, but it does work and works well, even when it's raining.

T1 Terry

__________________

You can lead a head to knowledge but you can't make it think. One day I'll know it all, but till then, I'll keep learning.

Any links to any sites or products is not an endorsement by me or do I gain any financial reward for such links 



Guru

Status: Offline
Posts: 7314
Date:

Never use spring washers.

A nut will work loose because the bolt & hole are not the correct size. When the hole is oversize there is room for micro movement & the nut will work loose whether it has a spring washer or not.

Rather than just making both holes a neat fit, is to tap the second piece of metal so the bolt will basically not move within the hole.

For additional insurance also use a Nyloc nut instead of a normal nut.

Put the effort in & tap holes & get proper tapping fluid.

Metric ISO coarse:

M4 pitch 0.7 hole 3.4mm
M5 pitch 0.8 hole 4.3mm (11/64)
M6 pitch 1.0 hole 5.1mm (13/64)
M8 pitch 1.25 hole 6.9mm
M10 pitch 1.5 hole 8.6mm (11/32)
M12 pitch 1.75 hole 13/32

Use a Taper tap. Then if needed an Intermediate tap, then Bottom tap. But since one is generally bolting two sheets, use a Taper tap.



__________________

Procrastination, mankind's greatest labour saving device!

50L custom fuel rack 6x20W 100/20mppt 4x26Ah gel 28L super insulated fridge TPMS 3 ARB compressors heatsink fan cooled 4L tank aftercooler Air/water OCD cleaning 4 stage car acoustic insulation.



Senior Member

Status: Offline
Posts: 386
Date:

cheers Terry ,

yes that is my main concern. Not so much being able to work the lifters into the system but how to maintain an appropriate level of structural security when travelling etc.

My panels are sized to provide sufficient power for my needs when laying flat, so it was more of a project thing really to see if I could.
It might be worth my effort to try on the car for ****s and giggles. Would be on a smaller scale and more manageable .

WAWT - I do love me a good nyloc nut. I do have me a couple of tap and die kits at home, dont recall where they came from though but they're not much chop. Only every good for working with soft metal like aluminium. Have pulled them out to try on other staff in the past but they've always got stuck back in the corner as useless. perhaps i need a better set.

__________________


Guru

Status: Offline
Posts: 1315
Date:

:lol: Coming from an industry that built big site cranes, nyloc nuts were something used on a back yard project because they are one use items and must be replaced each time or they no longer lock in place. Everything that could be thread tapped was thread tapped and every stainless bolt had a spring washer and flat washer of the same material.
With our installs on thin material we use nut-serts, a bit like a rivet but it has a thread inside. The pivoting points each end of the array that the nut and bolt came loose has since also been fitted with a stainless nut-sert so the hole didn't flog out the way the bolt hole did. Field testing shows up the weaknesses in any set up, so learning from your own vehicle is much better than learning from a customers vehicle :)

T1 Terry

__________________

You can lead a head to knowledge but you can't make it think. One day I'll know it all, but till then, I'll keep learning.

Any links to any sites or products is not an endorsement by me or do I gain any financial reward for such links 



Guru

Status: Offline
Posts: 7314
Date:

If tapping steel use good quality taps not the rubbish at the standard hardware store. It is critical to drill the right size hole & use a TAPER tap, not an INTERMEDIATE that is normally sold, & with tapping fluid. Turn the tap backwards a bit between every bit of a turn forward. Take is easy so you don't break the tap.



-- Edited by Whenarewethere on Wednesday 17th of July 2019 09:30:09 PM

__________________

Procrastination, mankind's greatest labour saving device!

50L custom fuel rack 6x20W 100/20mppt 4x26Ah gel 28L super insulated fridge TPMS 3 ARB compressors heatsink fan cooled 4L tank aftercooler Air/water OCD cleaning 4 stage car acoustic insulation.



Senior Member

Status: Offline
Posts: 386
Date:

ooh yes rivnuts. I've not long ago discovered them and have cause to try one out soon to hold on a bash plate to the under side of the pajero where the thread has gone.
I'm going to drill it out and stick on in there. I guess I'll see how well they hold in a touch scenario under the 4wd and getting beaten about.
That should give me some confidence in their staying power.....or not

So is the general consensus, that there isn't anyone angling their roof panels remotely or otherwise ?



cheers Brett.





__________________


Guru

Status: Offline
Posts: 1927
Date:

denmonkey wrote:

ooh yes rivnuts. I've not long ago discovered them and have cause to try one out soon to hold on a bash plate to the under side of the pajero where the thread has gone.
I'm going to drill it out and stick on in there. I guess I'll see how well they hold in a touch scenario under the 4wd and getting beaten about.
That should give me some confidence in their staying power.....or not

So is the general consensus, that there isn't anyone angling their roof panels remotely or otherwise ?
cheers Brett.

Hi Brett 

Do you have a tool to fit them or will you have it 'set' by a place that can set it correctly. No good otherwise for a tough use!

Jaahn

 



__________________


Senior Member

Status: Offline
Posts: 159
Date:

 

Here  are pictures of a couple of  quick & easy Isc testers with anderson connector and  also an adaptor in case of MC4 connectors.

One version uses a cheap "power meter" and the other uses a clamp on ammeter.

As you know, Voc is only part of the story. I recently tested a panel for which Voc was normal (~ 21V) but couldn't supply any current. I assume a high resistance joint or bad cell(s) somewhere.

Ken

Isc Tester2.jpg

 

 

Isc tester.jpg



-- Edited by kgarnett on Thursday 18th of July 2019 02:46:04 PM



-- Edited by kgarnett on Thursday 18th of July 2019 09:48:56 PM



-- Edited by kgarnett on Thursday 18th of July 2019 09:49:37 PM

Attachments
__________________


Senior Member

Status: Offline
Posts: 386
Date:

Ken you're a bloody genius.
I've got plenty of those meters and even more wire and andersons than I can poke a stick at.
Could knock one of those up in a few minutes. Could always just use my multi too but I don't have to make that , so have a zero fun factor.


Jaahn, don't tell me that cry.

I was wondering how they'd go in such situations. I've have a proper tool but am concerned it will eventually loosen and just spin inside the spot where its installed.

 

cheers Brett 



__________________


Senior Member

Status: Offline
Posts: 159
Date:

I must have been dreaming when I showed the use of a cheap power meter to measure Isc.

I have certainly used it to measure panel currents into a load etc, and thought that I had also used it to measure Isc.  But of course it cant because when measuring Isc the voltage is zero and thus can't power the meter, so no display.

Sorry about that !  no

Ken



__________________


Guru

Status: Offline
Posts: 1927
Date:

Hi Brett smile

I have never used nutserts myself so I cannot say much. But I have had problems with some over the years that were not set in place correctly or pulled up tight enough. Just mentioned it really. Seemed to be incorrect fitting that was the problem. A bash plate might be a test for it !confuse

Jaahn

 



__________________


Senior Member

Status: Offline
Posts: 386
Date:

kgarnett wrote:

I must have been dreaming when I showed the use of a cheap power meter to measure Isc.

I have certainly used it to measure panel currents into a load etc, and thought that I had also used it to measure Isc.  But of course it cant because when measuring Isc the voltage is zero and thus can't power the meter, so no display.

Sorry about that !  no

Ken


 

 

aww Ken, you have me so excited about my next free sunny day. Guess there is only one way to find out. 

Multi meter it is. Was fun while it lasted.        ... hang on, don't these meters also have an additional input on the side for them to remain on when the 'source' isn't active ? 

I think there is a little 3-4 pin connector on one end but I can't recall if it's for a power input  or whether it was for multil cell batteries like for Remote control batteries . 

Will have to suss it out. 

 

Thanks Jaahn for the clarification. I'm pretty committed to trying it out. If it doesn't work, I'll have to pull it and tap the existing hole but that means buying a kit to do so and a proper one wont be cheap for that size and my mate already has the bits for the riv set up. so it's free to try biggrin

I shall document my success or failure. 

 

actually whilst we're talking rivnuts, the mate who is lending it to me stuck 2 in the end of his awning, then placed a small eye bolt in both ends to attach guy ropes to. 

Basic but works very well and seems strong enough. saves tying the ropes around the arms etc and gives something to tie on to. 

not sure if that makes sense. 

 

 

cheers Brett

 

 

 

 

 

 

 



__________________


Senior Member

Status: Offline
Posts: 159
Date:

Brett,

 

You're right, there is a 3pin connector socket on the source end of the Power Meter for an external power supply to enable the meter to operate down to zero source volts.

The following text is copied from the "Watts Up" pwer meter manual but I imagine it similarly applies to the cheap copies.

Must try it !

 

Ken

 

6.5 Using Auxiliary Power

By connecting a DC power source (power supply, receiver battery pack, battery, etc.) of at

least 4.0 V to the 3-pin connector on the SOURCE side, the "Watt's Up" can measure down

to 0 V. This makes it possible to measure the characteristics of a single battery cell.

The 3-pin connectors socket will accept a Futaba J type, JR or HiTec type servo plug

connector. A suitable auxiliary power connector with wires attached is available for

purchase from our website.

Pin 1 is Negative (0 Volts), pin 2 (middle pin) is Positive. Pin 1 is the pin farthest from the

"Watt's Up" SOURCE wires. Pin 3, on meter versions 2.1 and above, is for reset of

accumulated readings. See below for description of reset operation.

When using Auxiliary power, you may see small measurement values when the SOURCE

and LOAD leads have nothing connected or are shorted together. It is neither unusual nor a

problem for there to be small values displayed in this situation. This will not affect

performance when making real measurements.



__________________


Guru

Status: Offline
Posts: 7640
Date:

I just use plenty of sicoflex . .

__________________
Whats out there


Senior Member

Status: Offline
Posts: 159
Date:

Brett,

 

OK, I tried powering the "Power Meter" from an external source and can now measure Isc current - All good ! biggrin

 

Ken 



__________________


Guru

Status: Offline
Posts: 1927
Date:

kgarnett wrote:

Brett,

OK, I tried powering the "Power Meter" from an external source and can now measure Isc current - All good ! biggrin

Ken 


 Hi Ken smile

Thanks for that info might be useful as I have a couple of those meters. Gees it is good to spread the knowledge about.biggrin

The problem with having a couple of meters is you get a couple of different readings tooaww  but I am not being paid to be precise now so I can wing it a bit confuse I have several multi meters too with the same problem.

Jaahn



__________________


Senior Member

Status: Offline
Posts: 386
Date:

hazaa to all involved. thanks for being the test bunny Ken.

You're right Jaahn, the only answer is to sell or give away all of your test gear, bar one unit, to someone who will very much enjoy them.
hmm, I'm not sure where you would find someone like that who would be so willing to help you out of that bind wink

Ken, If I can swing this with Jaahn, you wanna go halves in his stuff ?

cheers Brett



__________________


Senior Member

Status: Offline
Posts: 159
Date:

Yes, of course I'd be willing to help out Jaahn move his stuff.

It would just add to all my stuff which my wife classifies as junk. but of course in reality her stuff is junk and mine is all "good stuff"

She just doesn't understand.

Ken 



-- Edited by kgarnett on Friday 19th of July 2019 05:33:01 PM

__________________


Guru

Status: Offline
Posts: 1315
Date:

denmonkey wrote:

ooh yes rivnuts. I've not long ago discovered them and have cause to try one out soon to hold on a bash plate to the under side of the pajero where the thread has gone.
I'm going to drill it out and stick on in there. I guess I'll see how well they hold in a touch scenario under the 4wd and getting beaten about.
That should give me some confidence in their staying power.....or not

So is the general consensus, that there isn't anyone angling their roof panels remotely or otherwise ?



cheers Brett.




You can buy both steel and stainless steel rivnuts, maybe be even high tensile from a specialty supplier, but no idea how you would pull it :lol: If you have a rivnut that isn't holding properly, cut the bolt head off and drill it out, or if you manage to get the bolt out, use a bolt long enough to go all the way through the rivnut and enough for a nut and a couple of flat washers on the bolt shank as well. Screw the bolt through till there would be some thread sticking out the other end, then hold the bolt head and tighten the nut onto the 2 washers as tight as you think you can go without either stripping out the thread of an aluminium rivnut, or snapping the bolt in a steel rivnut. This will retighten the rivnut. If you use this method for high load bearing rivnuts then every time you tighten the nut up the bolt the rivnut is tightened and the bolt takes the load through all the threads of the rivnut. Never a problem with spinning rivnuts then. 

 

T1 Terry 



__________________

You can lead a head to knowledge but you can't make it think. One day I'll know it all, but till then, I'll keep learning.

Any links to any sites or products is not an endorsement by me or do I gain any financial reward for such links 



Guru

Status: Offline
Posts: 4375
Date:

The OKA has dozens of riv nuts in it from new. I am not much of a fan, but agree they do a job that is sometimes hard to do some other way. I have had many failures of the originals, sometimes due to corrosion and sometimes due to them spinning in the original panel.
I replace them with either steel or aluminium ones. It is useful to add a couple of tiny grooves in the panel with a small triangular file to give them some extra grip.
I have also used some big ones (M12). They can be pulled up by tack welding to the panel then pulling up with a bolt, washer and socket on a breaker bar. They rarely fail.

I often use m6 aluminium riv nuts in a piece of aluminium that is then glued to the skin of sandwich panel with Sikaflex 11FC to provide a high load attachment point to a relatively fragile skin.

P1030059E.JPG

Cheers,

Peter



Attachments
__________________

OKA196, 4x4 'C' Class, DIY, self contained motorhome. 960W of solar, 400Ah of AGMs, 310L water, 280L fuel. https://www.oka4wd.com/forum/members-vehicles-public/569-oka196-xt-motorhome
 

 



Senior Member

Status: Offline
Posts: 386
Date:

thanks boys, i do like the idea of chucking a weld on on it. I have a welder and am sure I could tack it but thats about as good as it would get.
I don't believe I should be trying to arc weld on vehicle. bad things happen dont they.

I've got a mix of the alu and steel nuts. Guess, I'll just suck it and see. keen to try them out for the first thime.

The reason I'm going with this, is where the bolt goes through the bash plate to hold it on, is into a square tube cross member of sorts.
so there's no getting behind it to do the usual stuff. :(

cheers

__________________