SHURflo accumulator model 182-100


I have a drinking water filter under the sink that has a very low flow rate.

This causes the pump to pulsate (cut in & out rapidly). The LEDs in the jayco are 12 volt (not multi voltage). They flicker when the pump is pulsating. One light has already failed. I turn the lights of now when using the filter. I believe it will eventually cause  failure of the pump or pressure switch.

I have purchased a shurflo accumulator to overcome this problem.

The instructions say the water flow can go (1) through the accumulator, or (2) be T,ed into the system & blank the outlet of the accumulator.

The second option would far easier. If I go this way does the air have to be bled form the water side of the accumulator?

Keen to hear from anyone who has fitted an accumulator or has knowledge of any pitfalls fitting one.

Cheers Pete

 



__________________


Guru

Status: Offline
Posts: 1743
Date:

 

Hi

it will not make much difference, any air in the water side will gradually be absorbed

The bladder should pretty well fill the space in the chamber, pushing out most of the airwink

 



-- Edited by oldtrack123 on Monday 26th of October 2015 09:55:11 AM

__________________


Guru

Status: Offline
Posts: 507
Date:

oldtrack123 wrote:

 

 

The bladder should pretty well fill the space in the chamber, pushing out most of the airwink

 



-- Edited by oldtrack123 on Monday 26th of October 2015 09:55:11 AM


 I didn't think about that. The accumulator is precharged to 30 psi. You are correct.

Thanks Pete

 



__________________


Senior Member

Status: Offline
Posts: 242
Date:

Sounds like you might have an undersize wiring problem as well. Although the pump uses bigger amperage it shouldn't affect your lights that much, we had a similar problem & replaced our supply wiring with heavier gauge to overcome the voltage drop caused by the pump.
The only thing that flickers the lights now is when the diesel heater is first turned on & that's only for a very short time.



-- Edited by The Doo crew on Monday 26th of October 2015 02:45:31 PM

__________________

The government cannot give anything to anybody that the Government does not first take from somebody else.



Senior Member

Status: Offline
Posts: 134
Date:

I had the exact same problem, all I did was get a 1/2" plastic tap from bunnings and 

placed it in the inlet line from the tank to the pump , I adjusted it back so as to restrict the flow to the pump

this slowed the flow enough for the pump to run Ok when you opened the filtered water tap

Bob



__________________


Guru

Status: Offline
Posts: 507
Date:

I've finally fitted the accumulator. With the 30 psi precharge the pump cut in pretty qiuckly. I dropped the pressure to 15 psi & now get approx 300 ml from the filter tap before the pump cuts in. Problem solved.

Cheers Pete



__________________


Guru

Status: Offline
Posts: 1743
Date:

wasn_me wrote:

I've finally fitted the accumulator. With the 30 psi precharge the pump cut in pretty qiuckly. I dropped the pressure to 15 psi & now get approx 300 ml from the filter tap before the pump cuts in. Problem solved.

Cheers Pete


 

Hi  Pete

15PSI is usually  more than adequate for RV use

Saves battery energy if  of grid.

Less risk of undetected leaks from connections under pressure

as you have found, less cycling l



__________________