check out the new remote control Jockey Wheel SmartBar Canegrowers rearview170 Cobb Grill Skid Row Recovery Gear Caravan Industry Association of Australia
Members Login
Username 
 
Password 
    Remember Me  
Post Info TOPIC: An on going problem with gas fridge


Member

Status: Offline
Posts: 18
Date:
An on going problem with gas fridge


My Dometic fridge, model RM 4211,  when running on gas in a breeze, the pilot flame will blow out if the vent is facing into the breeze. I'm not talking about Gale force winds, just any light breeze will shut the flame down. It will then ignite itself until the next puff of wind.

Before you all spring to your keyboards, let me outline these past 9 months trying to sort this out.

I took the van to a caravan repair establishment twice in late Jan. the first time they blew out the jet after taking the vent cover off. I had to take the van back again a week later and this time they slid the fridge out and took the jet into the workshop for a good air clean, all gas pipes had the same treatment. Even tried to blow the flame out manually. All OK for a short time.

The next Caravan Shop found that the main jet had not been cleaned and this was done with some rust being removed. All OK for a week or so...then

I have now decided to engage a Gas Engineer who is also mystified

I have spent over $500 so far and  am no wiser.

The things I have tried are, A new regulator, covering the vents, one at a time, then both together, blocking the bottom of the fridge with wood to prevent a through draft, I always park on level ground.......and lastly sharing this  mystery with you. 

If you have any suggestions or hints you would be my mate for ever

Yours in anticipation 

Russ



__________________


Guru

Status: Offline
Posts: 1743
Date:

 

HI

Are you certain it is the breeze blowing out the "Pilot" flame???

The flame should be enclosed & protected from direct breeze[surrounded by covers ]

Things to check:

[1]  the Aux control circuit  battery supply voltage is steady & at least 12V

[2]The flame failure  probe tip is in the pilot flame ..

[3]It is possible the flame failure probe or control is faulity,  but that would uisually still be a problem on high flame

.[4]the pilot flame is just to small ,due to:"

[a]low gas pressure

partly Clogged gas bypass valve orifice 

 

PeterQ



__________________


Member

Status: Offline
Posts: 18
Date:

PeterQ Thank you for  your thoughts. The flame is enclosed and that would explain why each gas engineer got down and blew like mad however the flame kept burning.

The latest engineer will be here in the morning and I will show him your, much appreciated, comments

 

Russ



__________________


Guru

Status: Offline
Posts: 1176
Date:

There isn't any need for me to say much more PeterQ is on the money..

I would be more thinking the flame failure probe is not properly in the flame..

 

Just by the by where do you find "Gas Engineers" I have been in the Gas industry for 30yrs and have never heard of them..smilesmile



__________________

oldbobsbus@gmail.com

 

www.graftoncountrymusic.com.au



Guru

Status: Offline
Posts: 1192
Date:

will watch this post with interest. My fridge on gas goes out if in strong wind - I gather not entirely unusual but most annoying when you forget to check then everything is thawed!

__________________

'Once you are infected with the travel bug you have it for the rest of your life - there is NO cure'

http://hukaroa.blogspot.com.au

 



Guru

Status: Offline
Posts: 1743
Date:

 

HI

Does your fridge have the flue venting ,directly out the side wall ??

if so, does it have a  tee  on the top with  an" open" end into the fridge compartment,  or just an elbow on the top of the flue?

PeterQ

 



__________________


Member

Status: Offline
Posts: 18
Date:

Hello PeterQ

I'm not sure, I will have a look in the morning and get back to you.

Thanks for your interest

Russ



__________________


Guru

Status: Offline
Posts: 1029
Date:

Re Venting the Flue, a friend has this device around 4inchs high and 2.5 inches wide that from memory is on the outside of his van that the flue feeds into. This device has sloping vertical sides ie like a vertical V, and each side has 3 or 4 holes about 5/8inch each. I think its to stop a breeze coming down the flue to blow out the flame.

Peter

__________________


Guru

Status: Offline
Posts: 1743
Date:

PeterInSa wrote:

Re Venting the Flue, a friend has this device around 4inchs high and 2.5 inches wide that from memory is on the outside of his van that the flue feeds into. This device has sloping vertical sides ie like a vertical V, and each side has 3 or 4 holes about 5/8inch each. I think its to stop a breeze coming down the flue to blow out the flame.

Peter


 Hi Peter

Yes, that is why I was asking the questionsmile

But it can be in different forms

The main thing is to not allow the breeze to push back down the actual heater flue.