Post Info TOPIC: Fuse help for Mobitronic MPA 50A


Senior Member

Status: Offline
Posts: 174
Date:
Fuse help for Mobitronic MPA 50A


Well I have searched the forum googled Google until it gave up and can't find the answer. I just finished repairing my spare Mobitronic MPS 50A and just need to know what type of fuse on the 240V side. The board has it printed as 15A 250V but it doesn't state if its  a fast or slow blow fuse. Can anyone here assist?

 

Cheers

Pete



__________________


Guru

Status: Offline
Posts: 1531
Date:

I'd just try it with a fast blow first. If it blows violently then there is still a problem with the device. If it only just ruptures then maybe the inrush current may be what has blown it, so then try a slow blow fuse. If it still blows, then again the unit is still faulty.

__________________


Senior Member

Status: Offline
Posts: 174
Date:

Thanks 03 troopy but the unit is fine now that I fixed it. I used a dummy fuse ( a piece of brass bar and it is ok but I would prefer the proper fuse in case I have a problem in the future
Cheers
Pete

__________________


Guru

Status: Offline
Posts: 1531
Date:

Using the brass bar as a replacement fuse is a sign of a very confident repairman.. lol. My advice as how to determine whether to use a fast or slow blow fuse still stands. The alternative is to see what is written on the old fuse and replace it with a similar fuse. The slow blow fuse will most likely have a T after the rating (eg. 240V 15A T). But you would have done this I guess, if you still had the old fuse.

__________________


Guru

Status: Offline
Posts: 1465
Date:

All Switch Mode Power Suplies use slow blow fuses. The waeco 240v ac to 25V dc 100watt powersupply uses a 3.15A fuse. The mobitronic is suposed to be 160 Watt supply. I would try a 4A sloblo & see how it goes. SMPS use slow blow as there is usualy fairly high in rush current on switch on.



__________________
D.L.Bishop


Senior Member

Status: Offline
Posts: 174
Date:

Many thanks fellas for the help. Its up and running again. Yes I was confident I had made the repairs ( well at least I think I was) and to find out if it worked the was all I had handy I had drilled it out for a model motor I am building so it was thin lol. I also found the fuse was 1.5 amp not 15A as I thought it was, so the dot when I cleaned off the dust so DeBe was right

Cheers

Pete

 



__________________


Guru

Status: Offline
Posts: 1531
Date:

and it had a "T"?
lol, I usually err on the safe side and instead of using a brass bar, I just wrap a pice of the tinfoil from a ciggy packet around the blown 3AG. T.I.C.

__________________


Senior Member

Status: Offline
Posts: 174
Date:

yep had a T. I used to do that too but I gave them away 20years ago. been caught without a way to light a van stove or campfire at times....a downside of giving up lol

Pete



__________________


Guru

Status: Offline
Posts: 1531
Date:

The 'T' stands for time delay, or slow blow.
umm i was kidding about the ciggy packet foil too.. ;)