check out the new remote control Jockey Wheel SmartBar rearview170 Beam Communications SatPhone Shop Topargee products
Members Login
Username 
 
Password 
    Remember Me  
Post Info TOPIC: 2011 Jayco StarCraft mains water bypass issue


Newbie

Status: Offline
Posts: 4
Date:
2011 Jayco StarCraft mains water bypass issue


Hi all, Greg here - as indicated, when I connect to mains water it simply bypasses and pours out of a short drain tube under the van- any ideas what the issue is -TIA

__________________


Senior Member

Status: Offline
Posts: 243
Date:

Blocked tank breather perhaps? Hose come off under van?

__________________
J. Price


Newbie

Status: Offline
Posts: 4
Date:

Thanks joda, my understanding is that the mains water feeds straight into vans water system bypassing the tanks altogether, or maybe I've got it wrong

__________________


Guru

Status: Offline
Posts: 736
Date:

Stenno2,

I could only see the first and second of your postings in this thread. Not much information for people to elaborate on. Do you have any more information or a photo?
On my Jayco, all the water lines are visible if I go under the van to follow the pipe network around. Is your system working when the water goes on the ground from under the van? Presumably you have looked under the van for leaking or disconnected pipes?

In my van, Jayco did not fit a Non Return Valve (NRV) on the delivery pipe from the pump. They thought the pump would act as a NRV. It did for a while but with high pressure town water supplies, that method fails and water flows back into the water tanks. My water tank fill pipes overflowed as they are slightly lower than the breather pipes. I fitted a NRV afterwards. If there is Non Return problem, and the breather pipes are lower than the tank fill pipes are lower than the fill pipe, some water could go on the ground while the system is connected to town water.

__________________


Newbie

Status: Offline
Posts: 4
Date:

Thanks Watsea. The tanks fill fine using each of the filler holes and the systems all work fine off the tanks, it is only when I connect the mains water so I can run off this instead of the tanks that this bypass occurs. I have checked the piping underneath and where the water is pouring out is a short tube about 30cms long and does not appear to be disconnected from anything else. I haven't actually checked to see if the internal systems are working as the volume of water pouring out seems to match the mains water flow. I suspect that you may be onto something with the NRV as I was unable to see anything like that inline.

__________________
Page 1 of 1  sorted by
 
Quick Reply

Please log in to post quick replies.

Tweet this page Post to Digg Post to Del.icio.us
Purchase Grey Nomad bumper stickers Read our daily column, the Nomad News The Grey Nomad's Guidebook