check out the new remote control Jockey Wheel SmartBar Canegrowers rearview170 Cobb Grill Skid Row Recovery Gear Caravan Industry Association of Australia
Members Login
Username 
 
Password 
    Remember Me  
Post Info TOPIC: Evakool BCD-60. 2010 model


Guru

Status: Offline
Posts: 1464
Date:
Evakool BCD-60. 2010 model


0.JPG1.JPG2.JPG3.JPG4.JPG5.JPG6.JPGWhats in a BCD-60 Evakool 2010 model, they use a Domus T26K compressor 12/24V DC & controller. The controller is a little diferent to a Danfoss controller also half the price to buy. Heres some  pictures & info on the unit. Also note the push on conectors have a locking tab on them. This particular fridge has a faulty temp control as well as no refrigerant & the leak is inaccessible due to a foamed in evaporator.



-- Edited by DeBe on Saturday 9th of February 2019 06:59:46 PM



-- Edited by DeBe on Saturday 9th of February 2019 07:00:27 PM

Attachments
__________________
D.L.Bishop


Guru

Status: Offline
Posts: 1464
Date:

More pics.CONTROL PCB.1.JPGCONTROL PCB.2.JPGPCB.1.JPGPCB.2.JPGPCB.3.JPGFAULT CODES.jpgPOWER SOCKET.2.JPG



Attachments
__________________
D.L.Bishop


Guru

Status: Offline
Posts: 1464
Date:

EVAKOOL.1.JPGEVAKOOL.2.JPGEVAKOOL.3.JPGEVAKOOL.4..JPGEVAKOOL.5.JPGEVAKOOL.6.JPGMore pictures.



Attachments
__________________
D.L.Bishop


Guru

Status: Offline
Posts: 3981
Date:

The ATMLU826 part marking means ...

ATML = Atmel

U = Industrial Matt/Tin

826 = week 26 of 2008 (or 2018?)

 

The part ID is on the next line:

04C = AT24C04C

08C = AT24C08C

https://datasheet.datasheetarchive.com/originals/library/Datasheets-UD7/DSARS0014708.pdf



-- Edited by dorian on Saturday 9th of February 2019 04:02:39 PM

__________________

"No friend ever served me, and no enemy ever wronged me, whom I have not repaid in full."

Lucius Cornelius Sulla - died 78 BC 

 



Guru

Status: Offline
Posts: 2339
Date:

where is the box they store the smoke in biggrin

cheers

blaze



__________________
http://blaze-therese.blogspot.com/


Newbie

Status: Offline
Posts: 1
Date:

Hi DeBe, I've got one of these about 15years old, Last time used was Jan this year was working fine, took it out of the shed today and it's not cooling properly and the compressor is only drawing 2.0A instead of normal 4.5A. Would this suggest it has a refrigerant leak? If so it certainly hasn't lost all the gas, it gets down to about 4degC but runs continuously to do that. Cheers



__________________


Guru

Status: Offline
Posts: 1464
Date:

It sounds like it has a very small leak. With low current & the evaporator is only partly frosted, then its low in gas.