hi all

I would like to fit a soft start unit to my aircommand ibis3 air conditioner

can anyone tell me how much they cost and the best place to get one.

thanks 

glenlee



__________________


Senior Member

Status: Offline
Posts: 419
Date:

When you mean soft start are you wanting to reduce the thump the aircon gives on startup?


__________________


Member

Status: Offline
Posts: 5
Date:

yes it is very annoying when it cycles on /off

__________________


Guru

Status: Offline
Posts: 723
Date:

To do what you want, you would have to go into the inner control of the A/C and intercept the feed to the compressor motor, and insert a soft start circuit at that point. Whilst I am sure it is not impossible, it would be very difficult.

__________________


Guru

Status: Offline
Posts: 1315
Date:

erad wrote:

To do what you want, you would have to go into the inner control of the A/C and intercept the feed to the compressor motor, and insert a soft start circuit at that point. Whilst I am sure it is not impossible, it would be very difficult.


The other method is to bleed off the high pressure side of the compressor back to the low pressure side so when the compressor started again it wasn't a virtually locked rotor start due to the pressure still on top of the piston. This bleed off solenoid could even remain open until the compressor reached full speed, this would reduce the high start current as well as quieten the restart because the compressor would be unloaded until it reached operating speed.

 

T1 Terry 



__________________

You can lead a head to knowledge but you can't make it think. One day I'll know it all, but till then, I'll keep learning.

Any links to any sites or products is not an endorsement by me or do I gain any financial reward for such links 



Guru

Status: Offline
Posts: 1482
Date:

I would think that you would have to go to Dometic or other company and look at the specs for their soft start systems and see if it could be adapted to use with your Ibis.

This is a link to the Harrier Dometic soft start inverter system. What a conversion would cost would have to asked of an Aircon specialist if you could use the electronics for the Ibis.

https://www.caravanrvcamping.com.au/dometic-harrier-inverter-caravan-airconditioner

 

Your post made me think about doing the same thing to my Dometic aircon.

Since the good ol USA seems to have lots of stuff for RV's I had a look online and saw this system.

https://www.microair.net/collections/easystart-soft-starters

 



-- Edited by Yuglamron on Friday 11th of January 2019 10:03:51 PM

__________________

 

 

 

 

Safe Travels



Guru

Status: Offline
Posts: 7640
Date:

Be aware US has 110v . I guess the compressor and fan could start on seperate timed relays ??

__________________
Whats out there


Guru

Status: Offline
Posts: 1378
Date:

Our three year old Ibis does not start up badly its preety smooth go figure? But theres been a lot of people complaining about it so thay definitely have a problem,cant figure out why ours is ok...



__________________


Member

Status: Offline
Posts: 21
Date:

Hi Aus Kiwi, I know its late for a reply and I really enjoy your posts.

in this case the link specifically shows reference to both 110 and 240 VAC.



-- Edited by RoamerAllWaze on Sunday 3rd of March 2019 08:14:47 PM

__________________


Guru

Status: Offline
Posts: 2206
Date:

T1 Terry wrote:
erad wrote:

To do what you want, you would have to go into the inner control of the A/C and intercept the feed to the compressor motor, and insert a soft start circuit at that point. Whilst I am sure it is not impossible, it would be very difficult.


The other method is to bleed off the high pressure side of the compressor back to the low pressure side so when the compressor started again it wasn't a virtually locked rotor start due to the pressure still on top of the piston. This bleed off solenoid could even remain open until the compressor reached full speed, this would reduce the high start current as well as quieten the restart because the compressor would be unloaded until it reached operating speed.

 

T1 Terry 


MMMMM what would happen when you suddenly drop the load on compressor running flat out????? 

 



__________________

Why is it so? Professor Julius Sumner Miller, a profound influence on my life, who explained science to us on TV in the 60's.



Guru

Status: Offline
Posts: 1315
Date:

Baz421 wrote:
T1 Terry wrote:
erad wrote:

To do what you want, you would have to go into the inner control of the A/C and intercept the feed to the compressor motor, and insert a soft start circuit at that point. Whilst I am sure it is not impossible, it would be very difficult.


The other method is to bleed off the high pressure side of the compressor back to the low pressure side so when the compressor started again it wasn't a virtually locked rotor start due to the pressure still on top of the piston. This bleed off solenoid could even remain open until the compressor reached full speed, this would reduce the high start current as well as quieten the restart because the compressor would be unloaded until it reached operating speed.

 

T1 Terry 


MMMMM what would happen when you suddenly drop the load on compressor running flat out????? 

 


As in? It is an electric motor, the max speed is governed by the voltage and frequency, but why would you dump the load while the compressor was still being driven, simply open the bleed back valve the same time as the power is cut to the compressor. As long as there was a non return valve the other side of the bleed back valve the high pressure refrigerant would still be there knocking on the door of the TX valve if the system uses one.

I had often wondered about the value of an accumulator like those used in hydraulics and water systems to store high pressure so the pump off time was extended and a softer start up period when the pump restarted while the pressure built up again. Inverter technology made such a system redundant so I never bothered to follow it up.

 

T1 Terry 



__________________

You can lead a head to knowledge but you can't make it think. One day I'll know it all, but till then, I'll keep learning.

Any links to any sites or products is not an endorsement by me or do I gain any financial reward for such links 



Guru

Status: Offline
Posts: 637
Date:

The newer Ibis 3 spin up the motor first for a few seconds before engaging the compressor clutch.
This is designed to reduce the start-up power load on generators, but makes the clutch clunk louder that the older design.

__________________