I GOT A GAS NON COMPLIANCE CERTIFICATE.


Bummer.

I got the fridge fixed but he gave me a gas non compliance certificate because there wasn't a 40mm internal hole in the floor behind the fridge as the bottom vent was 25mm above floor level. Something about  possible gas leaks could be a problem. He ticked the box saying not a risk and another saying he is not reporting it as it is only a minor problem.

Has anyone heard of this and if so have you got a mentioned hole and how is it done. 40mm is big and pests and vermin could get in, not to mention water when travelling. 

 



__________________

Live Life On Your Terms

DOUG  Chief One Feather  (Losing feathers with age)

TUG.......2014 Holden LT Colorado Twin Cab Ute with Canopy

DEN....... 2014 "Chief" Arrow CV  (with some changes)

 



Senior Member

Status: Offline
Posts: 236
Date:

Hi Doug,perhaps another opinion from a gas  type person would be in order,then go to A van  and let them fix their non compliant work.cheers Peter.



__________________

SOME  POLITICIANS  AND  BABIES  NAPPIES  SHOULD  BE  CHANGED  OFTEN FOR  THE SAME  REASON.

Duh


Guru

Status: Offline
Posts: 3240
Date:

Newie on me too Doug.  Give A'van in Melbourne a ring, ask for Geoff Van Bardwyck Junior, the factory Manager.  Or ring your local A'van dealer.   Tell them you want a compliance certificate that says otherwise, spelling it out. 

There should have been a gas compliance certificate with the van when you bought it ?????



__________________

Vic  - Mitsubishi Outlander and rear end tent....

 

 

 



 



Guru

Status: Offline
Posts: 2138
Date:

maybe another rule in QLD ???



__________________


Guru

Status: Offline
Posts: 834
Date:

Use a 50mm hole saw and then nail, glue or staple a piece of flywire over the hole from the top side.
 1 ,2 or even 3 holes is pretty standard on many vans.
Ozjohn.



__________________

Retired Engineer, Ex Park Owner & Caravan Consultant. 
Holden 2.8 Colorado - Roma Elegance 17'6" Pop Top.
Location: Mornington Peninsula Vic. 



Guru

Status: Offline
Posts: 1880
Date:

Gas vents have always been require to be place at the lowest point not necessarily the most convenient The gas been heavier than air will pool in any depression. If a look at the rules for carrying gases in enclosed spaces and not one tradies van would pass the regs. there is supposed to be a gas tight locker to house the bottles vented through an extruded mesh insert in the floor, Maybe Telstra and a few Local councils are the only units that may  comply.    NSW Wiorkcover are a bit slack in their policing of the regs until they kill someone.

 

 If your looking for an easy fix  a clip in eave vermin grate or a couple of the clip in cupboard vent up  through the floor  Or you can just use a hole saw put in a 50 mmm hole and glue on some metal fly mesh screen  Just make sure you seal the cut edges of the floor .



-- Edited by Wombat 280 on Saturday 13th of July 2013 03:50:24 PM

__________________

Pets are welcome but children must be leashed at all times



Senior Member

Status: Offline
Posts: 381
Date:

This is all I could find in the rule book.Cheers

6.10.2 Vents
A wall vent at floor level shall be provided in the refrigerator compartment, so that any
accumulation of leaked gas can escape to the outside'
6.10.3 Clearances
Refrigerators shall be installed within cabinet work such that the infiltration of combustion
prodicts into the compartment is minimized. Minimum clearances, where specified by the
manufacturer. shall be maintained.
6.10.4 Ventilation
In addition to the requirements listed in Section 7, ventilation at the rear of the unit and to
the exterior of the
-carayan
shall be provided to ensure the proper functioning of the
refrigeration unit. Unless specifically instructed otherwise by the manufacturer of the
refrilerator, the additional ventilation shall comprise openings located at the top and bottom
levels of the enclosed space. Each opening shall be of a free area not less than specified in
Table 6.1. The upp.i ventilation opening shall be located entirely above the
condenser/absorption fins.


__________________


Senior Member

Status: Offline
Posts: 394
Date:

Being LPG,it is heavier than air which would be why the rule is as it is. I find it hard to believe, but not impossible, that the van would be non compliant from the manufacturer. If it is, then there are a lot of not just Avans, but quite likely others too unless it's an oversight.

Not your problem and I for one would be going back to the dealers for clarification and/or rectification. Whilst easy to fix as posted above, it needs to be brought to the manufacturers attention in case it is an oversight. If it is, by doing that you may save someone an injury or worse.

__________________

Cheers Jeff

Ticking off the bucket list before we kick it!

200 TTD with Evernew 22'6" and 40+ years in the oil & gas industry, now retired. CMCA Member.



Chief one feather

Status: Offline
Posts: 17339
Date:

Thanks for the feed back so far everyone, as usual you are all great help.

I will be back in my home town and will be near Avan manufacturer mid to late August so will go armed with the paperwork from the fridge man and wait for their more than likely no reaction.

I will start off very nice about the whole thing but could change rapidly.



-- Edited by Dougwe on Sunday 14th of July 2013 08:46:24 AM

__________________

Live Life On Your Terms

DOUG  Chief One Feather  (Losing feathers with age)

TUG.......2014 Holden LT Colorado Twin Cab Ute with Canopy

DEN....... 2014 "Chief" Arrow CV  (with some changes)

 



Guru

Status: Offline
Posts: 3994
Date:

If the standards bodies genuinely cared about consumer safety, they would provide all the relevant standards documents as free downloads. In reality, all they care about is making a buck.


__________________

"No friend ever served me, and no enemy ever wronged me, whom I have not repaid in full."

Lucius Cornelius Sulla - died 78 BC 

 



Chief one feather

Status: Offline
Posts: 17339
Date:

If I end up having to the job myself which is on the cards I was thinking maybe drill the hole then glue and seal some PVC tube about 2" - 3" long in the hole flush with the inside of floor and hang down under, that maybe will stop the water getting in bit then the fly wire idea on to top section and that will solve the insects and vermin bit, maybe.

__________________

Live Life On Your Terms

DOUG  Chief One Feather  (Losing feathers with age)

TUG.......2014 Holden LT Colorado Twin Cab Ute with Canopy

DEN....... 2014 "Chief" Arrow CV  (with some changes)

 



Guru

Status: Offline
Posts: 1880
Date:

dorian wrote:

If the standards bodies genuinely cared about consumer safety, they would provide all the relevant standards documents as free downloads. In reality, all they care about is making a buck.


 Your right, the manufacturers should be aware of the  electrical and gas plumbing  Australian Standards  that cover Vans / MH and Boats and Transportable Homes .  The problem with Australian Standards  they are only guide lines unless called up at law.  While  we get that warm fuzzy feeling  thinking that there are organization such as ASA out there protecting us from ourselves   it's not entirely true.  The Committees that sit on  Standards are with vested interest as they are created from the industry  not any independent body . Next time you look at a ASA Publication read the Forward and the list of contributors Where you Universities mentioned  their contribution is normally  a proof read or Chair of meeting unless it effects their industry   .

 Since 1988 NSW WorkCover has called up a lot of standards as a means of cutting the delays in bringing down legislation and they are automatically reviewed every 5 years  even if only to re endorse what exists .  Legislative change  can take 5 years to get to a first reading and 10 years to be gazetted if it's straight forward  ,which it never is