SmartBar Mackay Festival of Arts Floriade Darwin International Film Festival
Members Login
Username 
 
Password 
    Remember Me  
Post Info TOPIC: Where do I start ? - 240 volt power


Guru

Status: Offline
Posts: 8735
Date:
Where do I start ? - 240 volt power


In that case I would think an Auto-electrician might be the way to go.  The guys will know for sure.

Cheers,

Sheba.



-- Edited by Sheba on Monday 4th of March 2013 11:39:16 PM

__________________
An it harm none, do what you will.


Guru

Status: Offline
Posts: 507
Date:

I think Julie means a 240v outlet (powerpoint to plug the toaster into). I'd say the one you can see, in the photo, is the 240v inlet (power into the van). If this is correct you would have to get an electrician who is familiar with regulations pertaining to caravans. You would have to use a point the same as the ones on the side of caravans (under the anex)

Cheers Pete

Sorry, you replied while I was typing.



-- Edited by wasn_me on Monday 4th of March 2013 11:43:20 PM

__________________


Veteran Member

Status: Offline
Posts: 29
Date:

Hi Everyone,

 

Just wondering who I would need to see to get some work done.

 

My point to plug into 240volt power is on the inside of my van, and in the past I have just left the drivers window down a smidgen and fed the lead through to the point.  I would like to get it changed so that only plug is on the outside, so I don't have to leave my windows down at all. See picture.

 

Do I just contact an electrician ?

 

Thanks,

 

Julie

 

 

 

 



Attachments
__________________

Julie



Guru

Status: Offline
Posts: 8735
Date:

I don't understand Julie.  That looks as though the plug for 240 V is already on the outside.  If that's the case, you don't need to have your windows down at all.

Cheers,

Sheba.



__________________
An it harm none, do what you will.


Veteran Member

Status: Offline
Posts: 29
Date:

Hi Sheba,

 

Sorry, the picture is not my van, that is how I would like it done on my van.

 

Thanks,

 

Julie

 



__________________

Julie



Senior Member

Status: Offline
Posts: 400
Date:

w t n
i think you need an electrician
im pretty sure auto electricians dont work on 240volt
possibly some of the caravan repair places have electricians on call

brian

__________________


Veteran Member

Status: Offline
Posts: 29
Date:

Thanks Sheba ...

 



__________________

Julie



Veteran Member

Status: Offline
Posts: 29
Date:

Hi Peter,

 

Sorry, I don't know all the terminology as yet.

 

I mean a socket on the outside of my van, that I plug a lead into, when I park at a caravan park.

 

Whatever that might be.

 

I will need a hole cut in my van, a little box setup I am guessing, and the socket.

 

I don't know who to take my van to, to get this done.

 

The socket I plug into is currently on the inside of my van, and I want it moved to the outside.

 

Thanks,

 

Julie

 

 

 



__________________

Julie



Veteran Member

Status: Offline
Posts: 29
Date:

Hi Brian,

 

Thanks, I will get some quotes tomorrow now I know.

 

Thank you.

 

Julie



__________________

Julie



Guru

Status: Offline
Posts: 4648
Date:

jetj wrote:

BG,

Does any sparky cut the hole and install the outside plug?  I was wondering myself whether to just call a sparky or go to MH place.


 Yes, any electrical contractor should do it. Really a simply job. If you get a quote/s run them by me if you wish and I'll tell you if the price sounds fair. One point, I have not seen the job or your rig, so I'm basing my comments on what you have said in the post and the photo provided.

Ken.



-- Edited by Big Gorilla on Tuesday 5th of March 2013 02:31:56 PM

__________________

Retired Airline Pilot and Electrician..

I'm not old, I've just been young a long time....Ken

Since light travels faster than sound, some people appear bright until you hear them speak.

 



Guru

Status: Offline
Posts: 4648
Date:

Yes, you need a licensed Electrician. I am one.  Where are you. I am presently in Tasmania and will be in Victoria around the Shepparton area first week of April.  I will be doing work like this as I travel. However if you are too far away from where I'll be, see a local electrical contractor, get a quote and go from there. I shouldn't imagine it would be a big or costly job..



__________________

Retired Airline Pilot and Electrician..

I'm not old, I've just been young a long time....Ken

Since light travels faster than sound, some people appear bright until you hear them speak.

 



Veteran Member

Status: Offline
Posts: 29
Date:

Hi Everyone,

 

This is the setup inside my van that I want moved to an external lockable box setup.

 

Thanks,

 

Julie


PS. I don't know why the photo is showing upside down but

it it is.

 


-- Edited by Where To Next on Tuesday 5th of March 2013 07:34:31 PM



-- Edited by Where To Next on Tuesday 5th of March 2013 07:35:46 PM

Attachments
__________________

Julie



Guru

Status: Offline
Posts: 1619
Date:

BG,

Does any sparky cut the hole and install the outside plug?  I was wondering myself whether to just call a sparky or go to MH place.



__________________

Janette



Senior Member

Status: Offline
Posts: 284
Date:

I guess this would be a 15amp power plug? As I believe that is what is used in all (most) caravan parks?

__________________

http://kiwis-in-oz.blogspot.com.au/



Guru

Status: Offline
Posts: 1619
Date:

Thanks BG, I did phone a MH/Caravan place and couldn't do an accurate quote without the vehicle but indicated about $500 which I thought was steep. I need the cut out switch and a couple of inside power points as well on the inside near the outside inlet. Would appreciate your opinion if expensive for job or not. The picture it as it is.

Thanks



__________________

Janette



Veteran Member

Status: Offline
Posts: 29
Date:

Hi Big Gorilla,

 

Thanks for that, I am in Queensland ...

 

Julie

 

 



__________________

Julie



Veteran Member

Status: Offline
Posts: 29
Date:

Hi Everyone,

 

This is the setup inside my van that I want moved to an external lockable box setup.

 

Thanks,

 

Julie


PS. I don't know why the photokeepsm
-- Edited by Where To Next on Tuesday 5th of March 2013 07:34:31 PM



Attachments
__________________

Julie



Veteran Member

Status: Offline
Posts: 29
Date:

Last photo ...

 



Attachments
__________________

Julie



Guru

Status: Offline
Posts: 2266
Date:

Hi Julie, the fixed Plug you have in the van is a 10amp, you really need to have a 15amp External Plug fitted to the outer wall of your van.  I am thinking the RCD would stay inside.

Cheers Neil



__________________

Neil & Lynne

Pinjarra 

Western Australia


MY23.5 Ford Wildtrak V6 Dual Cab / 21' Silverline 21-65.3

' 1260w Solar: 400ah Lithium Battery: 2000w Projecta IP2000 Inverter

Diesel Heater: SOG Toilet Kit: 2.5kw Fujitsu Split System A/c

 

 



Veteran Member

Status: Offline
Posts: 29
Date:

Hi Neil,

 

Thank you for letting me know that, I really appreciate it.

 

Is there any danger I using the 10amp one until I get it changed over ?

 

Thanks,

 

Julie

 

 



__________________

Julie



Guru

Status: Offline
Posts: 4375
Date:

Delta18 wrote:

Hi Julie, the fixed Plug you have in the van is a 10amp, you really need to have a 15amp External Plug fitted to the outer wall of your van.  I am thinking the RCD would stay inside.

Cheers Neil


 There is no requirement to have a 15A inlet.

Unless you are using lots of power (air conditioner) a 10A inlet would be quite sufficient and you will also be able to legally connect to a 10A outlet or a 15A outlet.

Stay 10A if that is all you need.

 

Cheers,

Peter



__________________

OKA196, 4x4 'C' Class, DIY, self contained motorhome. 960W of solar, 400Ah of AGMs, 310L water, 280L fuel. https://www.oka4wd.com/forum/members-vehicles-public/569-oka196-xt-motorhome
 

 



Veteran Member

Status: Offline
Posts: 29
Date:

Hi Peter,

I haven't yet made my decision about an air-conditioner, I am still researching.

Do you think I am better off putting a 15AMP in just in case, or get it changed over at a later date if need be ?

Thanks,

Julie

__________________

Julie



Guru

Status: Offline
Posts: 4648
Date:

image.jpgimage 1.jpgWhere To Next wrote:

Hi Everyone,

 Just wondering who I would need to see to get some work done.

 My point to plug into 240volt power is on the inside of my van, and in the past I have just left the drivers window down a smidgen and fed the lead through to the point.  I would like to get it changed so that only plug is on the outside, so I don't have to leave my windows down at all. See picture.

 Do I just contact an electrician ?

 Thanks,

 Julie

 

 

 

 


Ok, I've fixed up your photos which are below. What I suggest you do is locate an electrical contractor. Not an auto electrician. Use the Yellow Pages for the area you live in. Select a Contractor who is a one man operation, not a big Company and certainly not a MH/Caravan repair shop. A one man operation doesn't have the overhead like a big firm that has a warehouse, lots of vehicles and staff. The hourly rate will be $40.00 to $60.oo whereas a big firm could be $85.00 an hour upwards. A MH/Caravan Shop is a rip off evidenced by the estimate of $500.00 for the work you described.

The Caravan inlet you have is 10 amp which will be ok. If you decide to put an aircon in, change the inlet to 15 amp. Any other wiring or equipment changes will be included in the aircon quote. If the inlet can be put on the exterior wall directly behind where it is currently located, there will be no material use. You will be paying labor only. Maximum 2 hours work, say $80.00 cost to you. If you change the inlet to 15 amp, it costs $34.95 inc GST. A Contractor will add his profit anything from 10% to 50%.

The Hager 816T RCB is 16 amp single pole unit. OK for your use, including an air conditioner. Leave it in its current location.

Now if you want to install 2 power points close to the Hager RCB, it may not be possible to conceal the wiring behind the walls. Wiring will be in PVC pipe attached to the wall. Assuming the power points will be within 1 meter of the RCB, cost of pipe and wire will be roughtly $10.00. Power points cost $$18.70 each, and a mounting block cost $6.60 ea. Once again the Contractor will add his profit. Total material cost will be $60.00 plus profit 10% to 50%, plus labor. Once again maximum 2 hours labor, say $80.00. Total to do all the work including changing the inlet to a 15 amp unit would be around $288.00 to $300.00 allowing a 50% profit to the Contractor on materials. Most small Contractors would work on 20% to 25%, but you never know.

Once again I must emphasise that I have not seen your rig or the work involved, and I am only making an assessment on the basis of the information you have posted.

Hope all this helps. At least you have an indication of the cost which will allow you to evaluate any quotes you receive. I suggest you get 2 or 3 quotes. Also I cannot guarantee the hourly rate of a one man Contractor operation is $40.00. It may be more.

 

Regards, Ken. 



-- Edited by Big Gorilla on Wednesday 6th of March 2013 07:19:54 AM

Attachments
__________________

Retired Airline Pilot and Electrician..

I'm not old, I've just been young a long time....Ken

Since light travels faster than sound, some people appear bright until you hear them speak.

 

KFT


Guru

Status: Offline
Posts: 2437
Date:

G'day Ken,
thanks for that. I was not sure as the price looked "too good" to me but then I have not priced any imports and these days I would not even consider installing single outlets in a situation like this. you seem to know your stuff so I will not butt in any further.

You have given good advice although I would be looking at an hourly rate of $66.00 inc gst. $40 seems a bit on the low side these days.

avagreatday

frank



-- Edited by KFT on Wednesday 6th of March 2013 11:35:19 AM

__________________

Avagreatday.

Kathy and Frank currently at Home near Quirindi NSW



Guru

Status: Offline
Posts: 1619
Date:

BG,

Thanks so much for your post, so informative and helpful. I sensed the $500 quote as over the top, so did nothing further. Now I have an idea what to look out for I will pursue having it done. I think I prefer a 10 amp inlet if it is legal to run a fridge, kettle and toaster and not at the same time. That will avoid the implications of plugging into a normal house supply legally and not 15 amp.

Thanks for everyones contribution to this subject and the original poster for asking the question.



-- Edited by jetj on Wednesday 6th of March 2013 02:12:37 PM

__________________

Janette

KFT


Guru

Status: Offline
Posts: 2437
Date:

G'day everyone,

Big Gorilla, I am a bit put off by the price you quote for the double power points. My experience tells me they must be double pole and I have never been able to source them at trade price for less than about $45.00 each (HPM/Clipsal) are you quoting another brand or only single pole outlets?

frank

__________________

Avagreatday.

Kathy and Frank currently at Home near Quirindi NSW



Guru

Status: Offline
Posts: 4648
Date:

KFT wrote:

G'day everyone,

Big Gorilla, I am a bit put off by the price you quote for the double power points. My experience tells me they must be double pole and I have never been able to source them at trade price for less than about $45.00 each (HPM/Clipsal) are you quoting another brand or only single pole outlets?

frank


 Hi Frank. They are single outlets, not double. The maker is Chinese, a good unit approved for use in Australia. I've forgotten the brand name. Most electrical wholesalers now stock them and most do sell to the public. I have quoted a double pole unit which is required for a Caravan/Motorhome. I didn't go into too much technical detail as the member/s may not understand, but the electrician doing the job will know that double pole is required. The price you quoted is for a HPM or Clipsal double GPO, double pole. Single GPO double pole same brands, is $32.50 inc GST. The Chinese version is actually $20.57 as I had forgotten to add GST.

Ken.



__________________

Retired Airline Pilot and Electrician..

I'm not old, I've just been young a long time....Ken

Since light travels faster than sound, some people appear bright until you hear them speak.

 



Guru

Status: Offline
Posts: 8735
Date:

So glad the Guys came in on that one Julie.  I sure was way off base there, but I've learned something for future reference.

Cheers,

Sheba.



__________________
An it harm none, do what you will.


Guru

Status: Offline
Posts: 4648
Date:

Sheba wrote:

So glad the Guys came in on that one Julie.  I sure was way off base there, but I've learned something for future reference.

Cheers,

Sheba.


 Your comment was to get an auto electrician. That would be correct if the problem was in the 12 volt side of the installation or work was required on a car or caravan 12 volt wiring. But an auto electrician is not permitted to work on a 240 volt installation, unless he is appropriately licensed. Most are not.  An electrician such as myself can work on a 12 volt installation which is not too difficult in a caravan or motorhome, but ask me about car electrics and I'm completely lost !



__________________

Retired Airline Pilot and Electrician..

I'm not old, I've just been young a long time....Ken

Since light travels faster than sound, some people appear bright until you hear them speak.

 



Senior Member

Status: Offline
Posts: 465
Date:

Where in Queensland are you, Julie? Will be in the Bundy area for the next couple of weeks.

Darrell

__________________

Love the bush & our native environment. Conservationist, not a bloody Greenie.

1 2  >  Last»  | Page of 2  sorted by
 
Quick Reply

Please log in to post quick replies.

Tweet this page Post to Digg Post to Del.icio.us
Purchase Grey Nomad bumper stickers Read our daily column, the Nomad News The Grey Nomad's Guidebook